Please use this identifier to cite or link to this item: https://scholarhub.balamand.edu.lb/handle/uob/7270
Title: Comparison between the behaviors of fully encased cold-formed steel joists and hot-formed steel joists with prestressed concrete: Experimental analysis
Authors: Elkhansa, Hanadi
Barraj, Firas 
Ahmad, Samer
Affiliations: Department of Civil and Environmental Engineering 
Keywords: Composite beams
Prestressed concrete
Stiffness
Energy absorption capacity
Flexural capacity
Issue Date: 2024-01-01
Part of: Structural Concrete
Abstract: 
This paper investigates the behaviors of different types of prestressed concrete beams utilizing fully encased cold- or hot-formed steel joists. Twelve types divided into two sets of composite beams are assessed. Set 1 is composed of six beams utilizing cold-formed steel (CFS) joists distinguished by the cross-sectional steel-to-concrete ratios of 1%, 2%, and 3%, and the presence or absence of web openings. Set 2 has the similar composition but utilizes hot-formed steel joists. Four-point and three-point bending tests were conducted at the mid-span of the composite concrete beams. Key properties, such as strength, stiffness, flexural load capacity, ductility, energy absorption capacity, and failure modes, were used in the analysis. It was found that the specimens with CFS I-beam joists provided better performance compared to those with hot-formed steel joists. Also, the existence of web openings in the encased CFS beams enhances the ductility and energy absorption of the composite concrete beams.
URI: https://scholarhub.balamand.edu.lb/handle/uob/7270
ISSN: 14644177
DOI: 10.1002/suco.202300274
Ezproxy URL: Link to full text
Type: Journal Article
Appears in Collections:Department of Civil and Environmental Engineering

Show full item record

Record view(s)

15
checked on May 6, 2024

Google ScholarTM

Check

Dimensions Altmetric

Dimensions Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.