Please use this identifier to cite or link to this item: https://scholarhub.balamand.edu.lb/handle/uob/783
DC FieldValueLanguage
dc.contributor.authorNehme, Gabien_US
dc.contributor.authorDib, Michelineen_US
dc.date.accessioned2020-12-23T08:36:59Z-
dc.date.available2020-12-23T08:36:59Z-
dc.date.issued2016-
dc.identifier.urihttps://scholarhub.balamand.edu.lb/handle/uob/783-
dc.description.abstractMaintaining a comfortable fit in prosthetic socket for trans-tibial amputees (TTA) using design of experiment (DOE) and finite element model (FEM) to implement relief areas and holes in socket structure are important goals to help ensure better pressure distributions and successful rehabilitation. Design and fit of socket rely on patient acceptance and comfort. Sixteen sockets designed with different levels of reliefs and holes were investigated by Finite Element Model (FEM) and Design of Experiment (DOE) for flexibility and pressure distribution using ultra high molecular weight polyethylene (UHMWPE) and polyamide 6 (PA6) or Duraform then compared to conventional socket without any compliance. The purpose of this study was to assess performance of sockets with compliant features integrated into the socket wall to relieve in-socket pressure, increase flexibility and patient comfort during transtibial amputee gait. Reducing thickness at designated areas and hole implementation between the Patellar Tendon (PT) and Distal Tibia (DT) would decrease stiffness and increase prosthesis range of motion where flexibility is needed without compromising mechanical efficiency and the structural integrity of the socket. Different materials sockets 3 of each obtained by FEM/DOE analysis were manufactured and used by six amputees of the same age groups to measure the level of comfort and check the worn surfaces using scanning electron microscopy (SEM) and amputee performances after one year of usage. SEM and optical images were compared. The calculated stiffness of the two compliant sockets with holes are much less than the conventional sockets; they were more comfortable and showed significant decrease in wear debris over the course of the trial period.en_US
dc.language.isoengen_US
dc.subjectPressureen_US
dc.subjectWearen_US
dc.subject.lcshDesignen_US
dc.subject.lcshArtificial limbsen_US
dc.titleReducing wear debris and increasing lower-limb amputees' comfort by optimizing prosthetic socket design using local contact pressure relief and implementing appropriate holesen_US
dc.typeConference Paperen_US
dc.relation.conferenceASME International Mechanical Engineering Congress and Exposition (IMECE) (11-17 Nov 2016 : Pheonix Arizona, USA)en_US
dc.contributor.affiliationDepartment of Mechanical Engineeringen_US
dc.contributor.affiliationDepartment of Mathematicsen_US
dc.date.catalogued2019-04-09-
dc.description.statusPublisheden_US
dc.identifier.OlibID191240-
dc.relation.ispartoftextBiomedical and Biotechnology Engineeringen_US
dc.provenance.recordsourceOliben_US
crisitem.author.parentorgFaculty of Engineering-
Appears in Collections:Department of Mathematics
Department of Mechanical Engineering
Show simple item record

Record view(s)

54
checked on Nov 21, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.