Please use this identifier to cite or link to this item: https://scholarhub.balamand.edu.lb/handle/uob/6563
DC FieldValueLanguage
dc.contributor.authorArairo, Wahiben_US
dc.contributor.authorMasrouri, Farimahen_US
dc.contributor.authorAbdallah, Adelen_US
dc.contributor.authorRosin-Paumier, Sandrineen_US
dc.contributor.authorSraj, Omaren_US
dc.contributor.authorKhatib, Miladen_US
dc.date.accessioned2023-02-13T14:11:45Z-
dc.date.available2023-02-13T14:11:45Z-
dc.date.issued2022-12-26-
dc.identifier.urihttps://scholarhub.balamand.edu.lb/handle/uob/6563-
dc.description.abstractIn geotechnical engineering, geostructures with thermo-active functions establish direct thermal exchange between the ground and buildings. They can transfer energy from or into the ground to heat or cool a building. However, adapting foundation piles, completely or in part, to produce energy piles results in heat exchange with the soil, which changes the temperature of the soil and could thereby and affects the geotechnical properties and load bearing capacity of the geostructure. Most calculations of the bearing capacities of deep foundations conducted in France are currently based on in-situ testing results using a pressuremeter. Using finite element method to model the pressuremetric behaviour of a compacted soil subjected to thermo-mechanical variations is the main motivation for this work. In this study, several pressuremeter tests were conducted on a compacted illitic soil in a laboratory tank at temperatures between 1° and 40°C. The impact of temperature variation on the limit pressure (Pl), the creep pressure (Pf) and the Ménard pressuremeter modulus (EM) were determined. The results showed a significant decrease for both limit pressure (Pl) and creep pressure (Pf) with the increase of temperature. Numerical simulations of these tests were used to calibrate a bilinear constitutive model, taking into account temperature effects on soil compressibility within a coupled thermo-mechanical framework. Thereafter, a case study of a heat exchanger pile was simulated using the proposed approach.en_US
dc.language.isoengen_US
dc.subjectConductivityen_US
dc.subjectFinite element methoden_US
dc.subjectGeostructuresen_US
dc.subjectHeat transferen_US
dc.subjectPressuremeteren_US
dc.subjectTemperatureen_US
dc.titleTemperature effects on the design parameters of a geothermal pileen_US
dc.typeJournal Articleen_US
dc.identifier.doi10.34910/MCE.116.6-
dc.identifier.scopus2-s2.0-85147007930-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85147007930-
dc.contributor.affiliationDepartment of Civil Engineering and Constructionen_US
dc.description.volume116en_US
dc.description.issue8en_US
dc.date.catalogued2023-02-13-
dc.description.statusPublisheden_US
dc.identifier.openURLhttps://engstroy.spbstu.ru/userfiles/files/2022/8(116)/06.pdfen_US
dc.relation.ispartoftextMagazine of Civil Engineeringen_US
crisitem.author.parentorgIssam Fares Faculty of Technology-
Appears in Collections:Department of Civil Engineering and Construction
Show simple item record

Record view(s)

74
checked on Nov 21, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.