Please use this identifier to cite or link to this item: https://scholarhub.balamand.edu.lb/handle/uob/6079
DC FieldValueLanguage
dc.contributor.authorMilad Khatiben_US
dc.contributor.authorMelissa Loutfien_US
dc.contributor.authorHani Hamdanen_US
dc.contributor.authorArairo, Wahiben_US
dc.date.accessioned2022-09-22T06:30:20Z-
dc.date.available2022-09-22T06:30:20Z-
dc.date.issued2022-10-01-
dc.identifier.urihttps://scholarhub.balamand.edu.lb/handle/uob/6079-
dc.description.abstractThe dam is considered a huge structure that has multiple purposes in the life of a human. The most important role of a dam is the production of electricity, and the storage of a huge quantity of water. Therefore, it is very important to be vigilant in the studies made for it. Lebanon has indeed been designated as a seismicity country. However, the number of dams is increasing due to several natural consideration. Mseilha dam is an executed medium arch dam, which faced several problems during and after construction. The initial problem that faced a dam is the seismic force. This natural force is very dangerous for any structure, especially for a dam. It could increase the existing concrete stresses. These stresses will cause the development of cracks all along the dam. Once the concrete shows cracks, its resistance will decrease, and it will become more vulnerable to external effects. Several studies were made to fortify it and make it resistant to seismic force. To show the major effect of this force, two methods ‘pseudo-static’ and ‘response spectrum’ were applied to a medium arch dam. Therefore, to evaluate the performance of these two methods, the dam is modeled using finite element software. The obtained results show the importance of using the appropriate model in the design of such dams without taking the appropriate model.en_US
dc.language.isoengen_US
dc.publisherIWA Publishingen_US
dc.subjectFinite element softwareen_US
dc.subjectMedium arch damen_US
dc.subjectPseudo-staticen_US
dc.subjectResponse spectrumen_US
dc.subjectSeismic loadingen_US
dc.titleNumerical effect of seismic force on a medium arch damen_US
dc.typeJournal Articleen_US
dc.identifier.doi10.2166/wpt.2022.108-
dc.identifier.urlhttps://doi.org/10.2166/wpt.2022.108-
dc.contributor.affiliationDepartment of Civil Engineering and Constructionen_US
dc.description.volume17en_US
dc.description.issue10en_US
dc.description.startpage2083en_US
dc.description.endpage2099en_US
dc.date.catalogued2022-09-21-
dc.description.statusPublisheden_US
dc.identifier.openURLhttps://iwaponline.com/wpt/article/doi/10.2166/wpt.2022.108/90990en_US
dc.relation.ispartoftextWater Practice and Technologyen_US
crisitem.author.parentorgIssam Fares Faculty of Technology-
Appears in Collections:Department of Civil Engineering and Construction
Show simple item record

Record view(s)

108
checked on Nov 21, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.