Please use this identifier to cite or link to this item: https://scholarhub.balamand.edu.lb/handle/uob/2103
DC FieldValueLanguage
dc.contributor.authorNehme, Gabien_US
dc.contributor.authorDib, Michelineen_US
dc.date.accessioned2020-12-23T09:06:22Z-
dc.date.available2020-12-23T09:06:22Z-
dc.date.issued2011-
dc.identifier.urihttps://scholarhub.balamand.edu.lb/handle/uob/2103-
dc.description.abstractThe design of experiment (DOE) tool and finite element method (FEM) are very powerful for analyzing and optimizing the behavior of structures in a complex mechanic and geometry. In prosthetic sockets, great flexibility with a long range of spring-like action is needed. A finite element analysis was conducted investigating the stress and displacement distribution for different cases of Duraform (durable polyamide) and UHMWPE (ultra-high-molecular-weight polyethylene) sockets where relief was needed in certain pressure distribution areas experienced by the patient. A DOE using two-level factorial design was used to optimize these areas. Stresses and displacements were included in the model, and the desirability function was calculated. Higher deformation of the pressure relief areas was sought while preserving the socket structural integrity. Six socket cases associated with two different materials having 3 and 5 mm overall thicknesses were analyzed by FEM, and stresses and displacements of the five pressure relief areas were evaluated for all cases. High deformation of the socket relieved areas was optimized using DOE to assure the comfort of the amputee. The structural integrity of the socket and the optimized responses values with high desirability of the DOE model implied that Duraform socket A with 1.69 mm relief area could be the best design scenario for all cases.en_US
dc.format.extent13 p.en_US
dc.language.isoengen_US
dc.subjectAmputeesen_US
dc.subjectDesign of experimenten_US
dc.subjectProsthetic socketsen_US
dc.subjectFinite element analysis (FEA)en_US
dc.titleImpact of pressure distribution on the relief areas of prosthetic sockets for transtibial amputees using design of experiment and finite element analysisen_US
dc.typeJournal Articleen_US
dc.identifier.doi10.1097/JPO.0b013e318233159f-
dc.contributor.affiliationDepartment of Mechanical Engineeringen_US
dc.contributor.affiliationDepartment of Mathematicsen_US
dc.description.volume23en_US
dc.description.issue4en_US
dc.description.startpage170en_US
dc.description.endpage183en_US
dc.date.catalogued2019-04-08-
dc.description.statusPublisheden_US
dc.identifier.OlibID191208-
dc.relation.ispartoftextJournal of prosthetics and orthoticsen_US
dc.provenance.recordsourceOliben_US
crisitem.author.parentorgFaculty of Engineering-
Appears in Collections:Department of Mechanical Engineering
Show simple item record

SCOPUSTM   
Citations

5
checked on Nov 23, 2024

Record view(s)

50
checked on Nov 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.