Please use this identifier to cite or link to this item: https://scholarhub.balamand.edu.lb/handle/uob/735
DC FieldValueLanguage
dc.contributor.authorChaer, Toufic Alen_US
dc.contributor.authorGaubert, Jean-Paulen_US
dc.contributor.authorRambault, Laurenten_US
dc.contributor.authorNajjar, Maged B.en_US
dc.date.accessioned2020-12-23T08:35:52Z-
dc.date.available2020-12-23T08:35:52Z-
dc.date.issued2008-
dc.identifier.urihttps://scholarhub.balamand.edu.lb/handle/uob/735-
dc.description.abstractA three-phase shunt active power filter is generally used to compensate current harmonics demanded by non-linear loads, so that the source current remains quasi-sinusoidal and therefore the level of harmonic pollution in an electrical network is decreased. Most of the existing classical control methods for a three-phase shunt active filter usually lead to a non-linear control problem due to the non-linearity of the Park transformation. In a previous work, a compensated three-phase power distribution system has been successfully represented by a dasiasimplepsila linear state space model. Its state matrix contains a fundamental parameter used to extract the desired frequency component of any electrical signal. The linearity of the model enables one to use the control theory in a linear context in order to build a control system. In this paper, a three-phase shunt active filter is driven using output feedback control with Hinfin performance in order to reduce the number of measured outputs. The control method is mainly based on Linear Matrix Inequalities which are considered as a powerful tool for numerically solving control problems. The ability of the synthesized controller to provide an acceptable harmonic compensation is investigated through both numerical simulations on a prototype built in Simulink and experimental results.en_US
dc.format.extent6 p.en_US
dc.language.isoengen_US
dc.publisherIEEEen_US
dc.subjectHinfin controlen_US
dc.subjectLinear matrix inequalitiesen_US
dc.subjectNonlinear control systemsen_US
dc.subjectPower distribution controlen_US
dc.subjectPower harmonic filtersen_US
dc.subject.lcshState-space methodsen_US
dc.titleOutput feedback control of a three-phase shunt active power filteren_US
dc.typeConference Paperen_US
dc.relation.conferenceIEEE Power Electronics Specialists Conference (PESC) (39th : 15-19 June 2008 : Island of Rhodes, Greece)en_US
dc.contributor.affiliationDepartment of Computer Engineeringen_US
dc.description.startpage3819en_US
dc.description.endpage3824en_US
dc.date.catalogued2018-02-27-
dc.description.statusPublisheden_US
dc.identifier.ezproxyURLhttp://ezsecureaccess.balamand.edu.lb/login?url=http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4592550en_US
dc.identifier.OlibID178134-
dc.relation.ispartoftext39th IEEE Power Electronics Specialists Conferenceen_US
dc.provenance.recordsourceOliben_US
crisitem.author.parentorgFaculty of Engineering-
Appears in Collections:Department of Computer Engineering
Show simple item record

Record view(s)

54
checked on Nov 22, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.