dc.description.abstractThe purpose of this project is to study the mechanical building systems covering needs, safety and comfort through drainage and water system design, firefighting, heating ventilation and air-conditioning for Salem house, the Presidents house located inside the University of Balamand main campus. This project is a combination of the theoretical side, i.e. calculation and floor plans drawings along with the practical side, i.e. material selection related to each system. The design is made accurately, with theoretical and numerical calculations, based on the following sources: - ASPE: The American Society of Plumbing Engineers; - ASHRAE: The American Society of Heating, Refrigerating and Air-Conditioning Engineers. - NFPA: The National Fire Protection Association The findings of the study made are as follows: Cold Water System: - Net roof water tank capacity: 5,000 Liters; - Net basement water tank capacity: 15,000 Liters; - House Pump: Flow = 7.3381 GPM; Head = 14.44 m; - Booster set: Flow per pump = 18.75 GPM; Head of each pump = 12.3 m. Hot Water System: - Total storage capacity: 300 Liters, divided into 2 tanks of 150 Liters each; - Power input per tank = 21 KW; - Time required to heat each tank = 28 mins. Fire Fighting System: - Pro 5 MP Fire Extinguisher: in the kitchen, at the entrance and the exit of the stairs, in the storage areas, in the parking spaces, and on the roof; - Electrical Fire Extinguisher: in the electrical room. Sanitary Drainage System: - Total dfu of the house = 64. Cooling System: - Total cooling load of the house = 75.15 KW; - Total cooling load of the air-conditioners selected = 81.65 KW; - Total number of air-conditioners: 11 indoor and 11 outdoor units. Heating System: - Total heating load of the house = 48.79 KW; - Total heating load of the elements = 48.79 KW; - Total number of elements = 369.en_US
dc.description.statementofresponsibilityBy Chrystel Yazbeck, Elie Feghalien_US
dc.format.extentxiii, 129 p., [19] :ill., tables ;30 cmen_US
dc.language.isoengen_US
dc.rightsThis object is protected by copyright, and is made available here for research and educational purposes. Permission to reuse, publish, or reproduce the object beyond the personal and educational use exceptions must be obtained from the copyright holderen_US
dc.subject.lcshSalem House (University of Balamand)--Heating and Ventalationen_US
dc.subject.lcshSalem House (University of Balamand)--plumbingen_US
dc.titlePlumbing, heating, ventilation and air-conditioning of Salem houseen_US
dc.title.alternativePlumbing, heating, ventilation & air-conditioning of Salem houseen_US
dc.typeProjecten_US
dc.contributor.departmentDepartment of Mechanical Engineeringen_US
dc.contributor.facultyFaculty of Engineeringen_US
dc.contributor.institutionUniversity of Balamanden_US
dc.date.catalogued2013-07-09-
dc.description.degreeMS in Mechanical Engineeringen_US
dc.description.statusPublisheden_US
dc.identifier.ezproxyURLhttp://ezsecureaccess.balamand.edu.lb/login?url=http://olib.balamand.edu.lb/projects_and_theses/GP-Mec-100.pdfen_US
dc.identifier.OlibID134839-
dc.provenance.recordsourceOliben_US
Appears in Collections:UOB Theses and Projects
Show simple item record

Record view(s)

52
checked on Apr 25, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.