Please use this identifier to cite or link to this item:
https://scholarhub.balamand.edu.lb/handle/uob/2984
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Makhoul, Nisrine | en_US |
dc.contributor.author | Douaihy, Reem | en_US |
dc.contributor.author | Issa, Jouhaina | en_US |
dc.contributor.author | Sleiman, Roland | en_US |
dc.date.accessioned | 2020-12-23T14:32:45Z | - |
dc.date.available | 2020-12-23T14:32:45Z | - |
dc.date.issued | 2013 | - |
dc.identifier.uri | https://scholarhub.balamand.edu.lb/handle/uob/2984 | - |
dc.description | Includes bibliographical references (p. 92). | en_US |
dc.description | Supervised by Dr. Nisrine Makhoul. | en_US |
dc.description.abstract | This report includes the comparison between gravity loads and seismic loads of a seven story reinforced concrete residential building. Shear and moments of all beams, shear walls and columns were calculated according to gravity loads and then according to the direct displacement based design method. After calculating beams and slab thickness according to gravity loads, beams were designed using ACI moment coefficients where applicable and ETABS when ACI moment coefficients were not relevant. Shear and moments of both columns and shear walls were also attained. Then the shear and moments of all of the above specified elements based on the same dimensions and properties were calculated according to the direct displacement based design method, based on a specific drift limit and maximum causative earthquake applicable to Lebanon, in order to achieve the immediate occupancy performance level of the structure. Both results were compared and then typical components were designed and detailed according to the larger loads, whether moments and shear, using the Eurocodes 2 and 8. | en_US |
dc.description.statementofresponsibility | by Reem Douaihy, Jouhaina Issa, Roland Sleiman | en_US |
dc.format.extent | xvi, 97 p. :ill., tables ;30 cm | en_US |
dc.language.iso | eng | en_US |
dc.rights | This object is protected by copyright, and is made available here for research and educational purposes. Permission to reuse, publish, or reproduce the object beyond the personal and educational use exceptions must be obtained from the copyright holder | en_US |
dc.subject.lcsh | Structural analysis (Engineering)--Case studies | en_US |
dc.title | Comparison between gravity loads design and direct displacement based design of a seven storey residential building | en_US |
dc.type | Project | en_US |
dc.contributor.department | Department of Civil Engineering | en_US |
dc.contributor.faculty | Faculty of Engineering | en_US |
dc.contributor.institution | University of Balamand | en_US |
dc.date.catalogued | 2013-02-28 | - |
dc.description.degree | MS in Civil Engineering | en_US |
dc.description.status | Published | en_US |
dc.identifier.ezproxyURL | http://ezsecureaccess.balamand.edu.lb/login?url=http://olib.balamand.edu.lb/projects_and_theses/GP-Civ-110.pdf | en_US |
dc.identifier.OlibID | 132269 | - |
dc.provenance.recordsource | Olib | en_US |
Appears in Collections: | UOB Theses and Projects |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.